Calibration Steps:
- STAJE 1 - Activation and configuration
- Activate Programm Mode
- Read the Joystick Config
- Firmware
- Hardware
- Read the sensor Config
- STAJE 2 - Filter and Range settings
- Filter settings
- Activate Sensor #x for calibration
- Write Filter param in a Sensor #x
- Save Filter param in a Memory
- Read "Forward" (Max Positive direction of current Axis)
- Read "Backward" (Max Negative direction of current Axis)
- Range coefficient calculation
- Write Range param in a Sensor #x
- Save Range param in a Memory
- Filter settings
- STAJE 3 - Sensityvity and VOQ settings (Range adjustmen)
- Sensor Range calculation
- Read "Forward" (Max Positive direction of current Axis)
- Read "Backward" (Max Negative direction of current Axis)
- Sensitivity calculation
- Write Sensitivity param in a Sensor #x
- Read "Neutral" and calculate VOQ settings (Joistick is released on current Axis)
- Write VOQ settings in a Sensor #x
- Save Range param and VOQ settings in a Memory
- Sensitivity Adjustment
- Write Adjustment data in a Sensor #x
- If axis support more sensors - swich to the next and start from STAJE 2
- STAJE 4 - Compensation Table creation
- Activate All Sensors
- Activate "creation of Compensation Table" procedure
- Create Compensation Table (moving the Joistick from Max to Min position on current Axis)
- If the Joistick support more Axes swich to the next Axis / Sensor and start from STAJE 2
- Close the Programm Mode